Electricians in Stafford & Staffordshire

EICR Reports in Stafford for Landlords & Homeowners

Fixed wire inspection and testing for landlords, homeowners and businesses, with a clear written report and honest remedial quotes.

  • NAPIT registered
  • 8+ years' experience
  • Free, no obligation quotes
  • Certified to BS 7671
Electrician testing a circuit while producing EICR reports in Stafford

ABT Electrical Services Ltd produces EICR reports in Stafford and across Staffordshire for landlords, homeowners, letting agents and commercial clients. An Electrical Installation Condition Report is a documented inspection and test of the fixed wiring in a property, and it tells you in writing whether that installation is safe to stay in service.

We are NAPIT registered and test to BS 7671, the IET Wiring Regulations. You get the completed report with the schedule of circuit details and test results, plus a clear explanation of anything we have coded and what it will cost to fix.

What EICR reports in Stafford cover

An EICR is not a quick visual once over. We inspect and test the whole fixed installation: the consumer unit, the earthing and bonding arrangements, every final circuit, and a sample of accessories such as sockets, switches and light fittings.

  • Visual inspection of the consumer unit, accessories and visible cabling
  • Continuity of protective conductors, ring final circuits and bonding
  • Insulation resistance testing on each circuit
  • Earth fault loop impedance and prospective fault current
  • RCD operation and disconnection times
  • Polarity and correct connection throughout
  • A written report with observations, codes and recommendations

Understanding the codes on your report

The result of any inspection comes down to the codes recorded against the observations. There are four, and it is worth knowing what they mean before you read your own report:

  • C1 – danger present. Risk of injury. Immediate action is required, and we will make the installation safe before we leave.
  • C2 – potentially dangerous. Urgent remedial action is required.
  • C3 – improvement recommended. Not unsafe, and it does not make the report unsatisfactory.
  • FI – further investigation required. Something could not be resolved on the day and needs looking into.

A report is only satisfactory if it carries no C1, no C2 and no FI. C3 observations can be left, though they are usually worth doing when other work is happening anyway.

Landlord obligations in England

Since 1 July 2020 the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 have applied to new tenancies, and since 1 April 2021 to all existing tenancies. Landlords must have the fixed installation inspected and tested at least every five years by a qualified person, supply a copy of the report to tenants and to the local authority on request, and complete any C1, C2 or FI remedial work within 28 days.

The full requirements are set out in the GOV.UK guide for landlords. We can put your properties on a rolling cycle so certificates never lapse, and we quote for portfolios as well as single lets.

How often should other properties be tested?

  • Rented homes: at least every five years, or at change of tenancy.
  • Owner occupied homes: at least every ten years, and before buying or selling.
  • Commercial premises: typically every five years, or at change of occupancy.
  • Any property: after significant alteration, flood or fire damage.

What happens if the report is unsatisfactory?

An unsatisfactory result is not a disaster and it is not a sales tactic. It means specific, listed items need attention. Common causes are a board with no RCD protection, missing main bonding to gas and water, damaged accessories, and DIY additions that were never tested. We quote the remedial work item by item so you can see exactly what you are paying for, and we are happy for you to get that work done by someone else.

Depending on what the report finds, the fix might be a consumer unit upgrade, targeted repairs, or a full or part rewire. Once the work is complete we re-test and issue the certification. For anything else, see our full range of electrical services.

Areas we cover for EICR reports in Stafford

We carry out EICR reports in Stafford and across the surrounding towns and villages. Being based in the town itself keeps the whole area within easy reach, and we regularly work in:

  • Stafford
  • Stone
  • Penkridge
  • Rugeley
  • Cannock
  • Eccleshall
  • Gnosall
  • Great Haywood
  • Hixon
  • Weston

If you are a little further out across Staffordshire, call 07415 160779 and we will tell you honestly whether we can get to you.

EICR reports in Stafford: frequently asked questions

How often do I need an EICR?

For a rented home in England the fixed wiring must be inspected and tested at least every five years under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020. Owner occupied homes are recommended at least every ten years, and most commercial premises every five years or at change of occupancy.

How long do EICR reports in Stafford take to complete?

A domestic EICR on an average house usually takes between two and four hours, depending on the number of circuits and how accessible the consumer unit, sockets and light fittings are. Larger or commercial installations take longer. You receive the completed report shortly afterwards.

What do the EICR codes C1, C2, C3 and FI mean?

C1 means danger is present and immediate action is required. C2 means potentially dangerous and urgent remedial action is required. C3 means improvement is recommended but the installation is not unsafe. FI means further investigation is required. A report is only satisfactory if there are no C1, C2 or FI codes.

Is an EICR a legal requirement for landlords?

Yes, in England. Since 1 July 2020 the regulations have applied to new tenancies and since 1 April 2021 to all existing tenancies. Landlords must obtain a report at least every five years, supply a copy to tenants and to the local authority on request, and complete any required remedial work within 28 days.

How much does an EICR in Stafford cost?

The price depends on the number of circuits and the size and type of the property, so a one bedroom flat and a five bedroom house are not comparable. Tell us the property size and the number of consumer units and we will give you a free quotation before booking.

Checked, rated and reviewed

Our work is listed and reviewed independently. Read verified customer feedback before you book, or see our electrician reviews in Stafford.

Checkatrade logo – ABT Electrical Services Ltd reviews
TrustATrader logo – ABT Electrical Services Ltd reviews
Google Reviews logo – ABT Electrical Services Ltd reviews
NAPIT registered electricians in Stafford

Where to find us

ABT Electrical Services Ltd is based in Stafford and works throughout Staffordshire. Please note that our registered address is for correspondence only – we do not operate a public office or trade counter.

ABT Electrical Services Ltd
Mount Pleasant Barn
Stafford, Staffordshire ST17 0RA

07415 160779
info@abtelectricalservicesltd.co.uk

Opening hours

Monday – Saturday8:00am – 6:00pm
SundayClosed
Arrange a quotation

Get a free quote for EICR reports in Stafford

Need a report for a tenancy, a sale or your own peace of mind? All quotes for EICR reports in Stafford are free and carry no obligation. Call 07415 160779 or request a callback and we will get straight back to you.